KillTest Exam:HP0-841 Questions and Answers
首頁 >> HP >> HP MASE >> "HP MASE HP0-841"題庫

HP0-841

Designing and Implementing HP SAN Solutions

HP MASE HP0-841考試題庫由KillTest認證題庫網資深IT認證講師和HP MASE產品專家結合PROMETRIC或VUE的真實HP0-841考試環境最新原題傾心打造。

題庫覆蓋了當前最新的真實考題,並且全部附有正確答案,我們承諾題庫對HP MASE HP0-841(Designing and Implementing HP SAN Solutions)考試原題完整覆蓋。HP0-841題庫助您輕鬆通過認證考試,一次不過全額退款。

Designing and Implementing HP SAN Solutions

HP0-841
認證編號 Q&A 更新 價格(美元)

HP0-841

187 Q&A 2008-12-01 $ 89

HP MASE HP0-841(Designing and Implementing HP SAN Solutions)考題由我們的資深IT認證講師和HP MASE產品專家精心打造,包括了當前最新的真實HP0-841考題,全部附有正確答案

所有購買KillTest HP0-841 題庫的客戶都將得到60天的免費升級服務,保證了客戶的一次通過率。KillTest IT認證題庫網助您一次通過HP MASE HP0-841考試。

1、本題庫源自合作考試中心的真實考試原題,截屏后由我們的專業團隊匯總整理,再經過合作培訓中心資深IT認證講師對考題校對,保證了認證考試題庫的專業品質,題庫試題正確率100%,對HP0-841認證考試考題覆蓋率96%以上。您只需在參加HP MASE HP0-841認證前整體學習下本題庫,必定可以輕鬆完成考試,一次通過認證。

2、KillTest 實行“一次不過全額退款”承諾。如果您購買了我們的《HP0-841 Exam》考題,只要不是首次通過,憑蓋有PROMETRICVUE考試中心鋼印的考試成績單,我們將退還您購買HP0-841題庫的全部費用,絕對保證您的利益不受到任何的損失。(全額退款詳情)

3、作為亞太地區最專業的IT認證試題題庫供應商,我們提供完善的售後服務,我們對所有購買題庫的客戶提供跟蹤服務,在您購買考題后的60天內,享受免費升級考題服務,如果在這期間,認證考試中心對HP0-841考題做出修改或變題,我們會在第一時間更新相關題庫,并免費提供給您更新下載。

Designing and Implementing HP SAN Solutions(HP0-841 Exam)屬於HP MASE認證考試中的一門,如果需要取得HP MASE證書,您可能還需要參加其他相關考試,詳情可訪問HP MASE認證專題,在那裡,你將看到所有HP MASE認證相關考試科目。

HP0-841:下载HP0-841考试题库演示部分(PDF格式)HP0-841下載

HP0-841题库部分演示(DEMO)

1.What are the three types of fabric zoning on B-series switches? (Choose three.)
A.static zoning
B.software zoning
C.hardware zoning
D.mixmode zoning
E.QuickLoop zoning
Correct:B C D
2.In a single fabric, when multiple paths exist between a host and its storage, which statement is true?
A.The result could be an unstable fabric.
B.Load sharing is automatically set to static.
C.The FSPF protocol determines best route.
D.The path used is determined by port priority.
Correct:C
3.What is the correct statement about zoning in an interoperable fabric?
A.WWPN zoning is the only allowed method.
B.A mixture of domain ID, port number and WWPN zoning is allowed.
C.Domain ID and port number zoning are the only allowed methods.
D.Zoning is not allowed. The only way to segment a fabric is using the VSAN technology of C-Series switches.
Correct:A
4.What is the maximum distance per cable segment using 9/125 micron single-mode cable and long wavelength 2 Gb SFPs?
A.1 km
B.5 km
C.10 km
D.35 km
E.100 km
Correct:C
5.What is the internal M-series switch latency of a HP Fibre Channel switch?
A.between 1us and 2us maximum
B.3us
C.5us
D.33us
E.650us
Correct:A
6.Three LUNs, sda, sdb and sdc, are connected to a Linux server. You shutdown the server and physically remove sdb. What happens after the server reboots?
A.The LUNs sda and sdc are accessible, LUN sdb is not listed in the device scan.
B.The LUN sda is accessible, LUN sdc is now sdb and accessible using this name.
C.The LUNs sda and sdc are accessible, LUN sdb is listed as offline in the device scan.
D.The LUNs sda and sdc are accessible, LUN sdb is renamed into sdvb simulating a virtual device.
Correct:B
7.What is a Fibre Channel fabric?
A.one or more switches connected together, sharing the same name and routing table
B.two or more switches connected together, sharing the same name and routing table
C.one or more switches connected together, each having its own independent name and routing table
D.two or more switches connected together, each having its own independent name and routing table
Correct:A
8.Which three infrastructure components are supported from multiple vendors in an HP Open heterogenous SAN? (Choose three.)
A.hubs
B.switches
C.ATM gateways
D.storage systems
E.operating systems
Correct:B D E
9.Which three operating systems are supported in an HP heterogeneous SAN? (Choose three.)
A.HP NSK
B.IBM AIX
C.IBM OS400
D.Tru64 UNIX
E.Microsoft Windows 2003 Server
Correct:B D E
10.Which software module of HP OpenView Storage Area Manager (SAM) can you use to control the access of a managed host to a managed storage device?
A.Storage Builder
B.Storage Allocater
C.Storage Accountant
D.Storage Node Manager
Correct:B
11.Which HP SAN Management tool is a highly scalable, Java-based application that manages multiple B-Series switches and fabrics in real-time?
A.HP StorageWorks Fabric Manager
B.Management Appliance Software v2.1
C.HP OpenView Storage Node Manager
D.HP StorageWorks High Availability Fabric Manager (HAFM)
E.HP OpenView Storage Management Appliance III and HP OpenView Storage Management Appliance software v2.1
Correct:A
12.In Web Tools, which is a valid switch state?
A.down
B.marginal
C.segmented
D.reconfiguring
Correct:A
13.In the SAN configuration, assume a goal of redundancy for everything. How many Storage Management Appliances are needed?

A.1
B.2
C.4
D.6
Correct:B
14.What are HP SAN management strategies? (Choose two.)
A.automated policy based management
B.policy based backup using the storage management appliance
C.automatic performance optimization using sophisticated high performance management agents
D.storage virtualization using in-band management functionality of the storage management appliance
E.simplified, centralized storage management using standardized web based GUIs residing on a storage management appliance
Correct:A E
15.What characteristic has the greatest impact on disk performance?
A.bus type
B.drive latency
C.I/O transfer size
D.upgrade from a 1Gb/s HBA to a 2Gb/s HBA
Correct:B
16.What is throughput?
A.the number of requests processed per second
B.the number of I/O requests satisfied per unit of time
C.the amount of time a device needs to process a request
D.the time a device takes to process a request from issuance to completion
Correct:B
17.What can you do to minimize communication delays between a host and its storage subsystem?
A.cross couple multiple ISLs
B.ensure there is at least one switch hop
C.connect the two devices to the same switch
D.configure a maximum of four active host ports per ISL
Correct:C
18.A company is running an application that is READ intensive. They are more concerned with effective READ performance than WRITE performance. They have a limited number of disks so they need to minimize RAID overhead. What type of RAID should they use?
A.RAID 0
B.RAID 1
C.RAID 1+0
D.RAID 5
Correct:D
19.Which statement applies to trunking on B-Series switches?
A.Oversubsciption is impossible with trunking.
B.If one ISL of a trunk fails, the whole trunk fails.
C.Trunking increases the availability because an I/O is not interrupted, even if the master ISL of a trunk fails.
D.Trunking is more efficient than individual ISLs because it is less probable that congestion will be experienced.
Correct:D
20.The sum of the wait time (in queues) and the service time is _____.
A.data rate
B.request rate
C.response time
D.utilization time
Correct:C
21.What is the function of the HBA in an HP heterogeneous SAN?
A.allows a server to communicate with other fabrics
B.allows a server to communicate with other SAN devices
C.provides a direct fiber interconnect between the server and the storage system
D.provides a direct SCSI interconnect between the server and the Fibre Channel switch
Correct:B
22.What is a purpose of the HP Adaptive Infrastructure?
A.extension of service levels across the enterprise
B.IT environment adaptation to changing business requirements
C.automated management of fixed cost
D.simplified and centralized security management
Correct:B
23.Which statement describes the HP Adaptive Infrastructure?
A.It must be specifically designed for one application.
B.It syncronizes business and IT to rapidly respond to new business needs.
C.It is a fixed solution which meets the customer requirements for the next decades.
D.It is a bundle of hardware and management software which meets the requirements of all enterprise customers.
Correct:B
24.What describes the HP method to implement LUN masking on SAN storage systems?
A.VSAN
B.VersaStor
C.persistant binding
D.SSP (Selective Storage Presentation)
Correct:D
25.What are benefits of a SAN? (Choose two.)
A.data security
B.serverless backup
C.centralized storage
D.direct connect storage
E.LAN-based data movement
Correct:B C
26.What available resource should be referenced to find the latest tested software and hardware in HP supported Enterprise Backup Solutions ?
A.SPOCK
B.EBS Compatibility Matrix
C.Enterprise Backup Solution Design Guide
D.HP StorageWorks SAN Design Reference Guide
Correct:B
27.What are backup zones created to do? (Choose three.)
A.support two tape drives
B.restrict the number of servers
C.limit access to the tape libraries
D.isolate LVD and HVD tape libraries
E.separate tape libraries by OS platforms
Correct:B C E
28.In HP OpenView Storage Data Protector, what is zero downtime backup (ZDB)?
A.online backup
B.backup from disk to disk
C.direct backup from disk to tape
D.backup from snapshot or mirror
Correct:D
29.What are two advantages of centralized LAN backup? (Choose two.)
A.shared libraries
B.automated operation
C.no single point of failure
D.centralized management
E.does not interfere with LAN bandwidth
Correct:B D
30.A customer has multiple disk subsystems in a heterogeneous SAN that includes a mix of Sun and Windows 2003 Servers. Each server currently has its own tape backup device. Currently, backup requires 16 hours and requires three operators. How can an EBS SAN solution benefit this customer? (Choose two.)
A.It decreases LAN throughput.
B.It simplifies backup management.
C.It better utilizes hardware investment.
D.It allows the concurrent use of all host-based tape drives.
E.One server can better handle all the backup for the LUNs in the SAN.
Correct:B C

KillTest IT認證題庫網專業提供HP MASE HP0-841最新題庫下載,完全覆蓋HP0-841考試原題。HP0-841:HP MASE HP0-841 Questions and Answers,Designing and Implementing HP SAN Solutions

   
密碼:
購物車目前選購了 0 件題庫